HomeEvery1Microgrid
Every1
Microgrid Energy Management System

Your site, run as a microgrid.

Every panel, consumer and source — monitored live, balanced automatically, protected by priority.

Every1 EMS sees your whole electrical site: grid connection, solar, storage, generator, sub-panels and consumers. It keeps the site inside its limits, uses on-site energy first, curtails lower-priority loads, and keeps emergency panels powered — including when the grid goes down.

Request a DemoSee the outage sequence
Who gets power first
P1Emergency & criticalnever curtailed
P2Essential operations
P3EV charging
P4Non-essentialcurtailed first
Enforced on the main panel and every intermediate panel, every second.
Live Canvas

Any Site Can Be a Microgrid

A public charging site, a residential building or a commercial center — add solar, storage or a generator and Every1 runs it as a microgrid. Simulate a peak or a grid outage and click any card.

EVERY1
Energy management › Panel architecture › Harbor Retail CenterMicrogridLive
Site
Energy assets
Simulate
Grid connection▲ supplyingCONTRACT200 kWNOW132 kWSolar PV▲ generatingNOMINAL60 kWNOW60 kWBattery storage▼ chargingNOMINAL50 kWNOW30 kWGeneratorstandbyNOMINAL80 kWNOW0 kWMain panelEvery1 live budgetBUDGET260 kWREQUESTED192 kWSERVED192 kWParking panelSub-panel · 72 kW nowPHYSICAL100 kWVIRTUAL80 kWBuilding panelSub-panel · 120 kW nowPHYSICAL220 kWVIRTUAL200 kWStaff chargersP3▼ full speedREQ.22 kWNOW22 kWVisitor DCP3▼ full speedREQ.50 kWNOW50 kWRefrigerationP1▼ protectedREQ.30 kWNOW30 kWLighting & POSP2▼ runningREQ.50 kWNOW50 kWComfort HVACP4▼ runningREQ.40 kWNOW40 kW
260 kW budget192 kW served0 kW deferred▲ supplying▼ drawing⇅ both waysClick any card · illustrative values
How It Works

See It. Balance It. Protect It.

01

Monitor

A live energy model of the site, built from its real panel hierarchy on a visual canvas — main panel, intermediate panels, consumers and sources on one screen, with data available via API.

02

Balance

A power budget recalculated continuously: connection limit, minus building load and reserve, plus live generation. It drives every charger and flexible load on site.

03

Protect

Priority tiers decide who gives way first. Emergency and critical panels keep their reserved capacity whatever happens upstream.

Priority-Based Load Management

The Right Load Gets Power First

You define what matters on your site. Every1 enforces it automatically, every second — on the existing grid connection.

Priority 1

Emergency & critical

Life-safety, server rooms, cold storage, medical. Capacity is reserved and never curtailed — on grid or off.

Priority 2

Essential operations

The loads that keep the business running, served before anything flexible.

Priority 3

EV charging

Chargers share the live budget dynamically, per phase and per panel, through Every1 charging management.

Priority 4

Non-essential

Comfort HVAC, signage and deferrable loads are limited first when the site approaches its limit.

When the Grid Goes Down

The Lights That Matter Stay On

1

Detect

Metering shows the grid source is gone. Every1 switches the site budget to off-grid mode immediately.

2

Rebuild the budget

Available power is recalculated from storage state of charge, live solar and generator output.

3

Shed by priority

Non-essential loads are shed, charging drops to a minimum or pauses, essential loads are trimmed only if needed.

4

Protect & restore

Emergency panels stay powered throughout. When the grid returns, loads come back in priority order.

Islanding itself is performed by the site's inverter or transfer switch. Every1 decides what runs on the power that is available.

Platform

One EMS — Four Modules

Energy Monitoring

the whole site, live

  • Every panel, consumer and source as a live energy node
  • Grid, solar, storage and generator metering
  • Building-wide consumption on one screen
  • Real-time data available via API

Site Topology

your electrical architecture, visual

  • Build the panel hierarchy on a visual canvas
  • Main panel and any depth of intermediate panels
  • Physical and virtual limits on every panel
  • Server-enforced topology rules

Dynamic Load Management

multi-source, priority-aware

  • Live budget includes on-site generation
  • Priority tiers protect critical panels
  • Phase-aware allocation across chargers
  • Safe fallback if a meter goes offline

EV Charging Management

built in, not bolted on

  • Any OCPP 1.6 charger
  • Billing, invoicing and time-of-use rates
  • Tenant and driver portal
  • Payment terminals for walk-in customers
Who is it for

Sites That Run on More Than the Grid

Commercial sites

  • Solar on the roof, storage in the yard
  • Use on-site energy before buying from the grid
  • Charging for staff, fleets and visitors

Offices & campuses

  • Many buildings, one connection
  • Add chargers without a grid upgrade
  • Central view across all panels

Critical facilities

  • Healthcare, data rooms, cold chain
  • Emergency panels with reserved capacity
  • Generator and storage backup orchestrated
Standards & Integration

Open by Design

Compliance & Standards

  • AFIR compliant — EU regulation for alternative fuels infrastructure
  • OCPP 1.6 / OCA compliant — open charge point protocol
  • ISO 27001 — information security certified
  • Encrypted communications — private APN network

Works With Your Equipment

  • Hardware-agnostic — any charger, inverter, battery or generator that is metered
  • Battery storage — state of charge and availability feed the live budget
  • Smart meters — per panel, per source, per consumer
  • afik-st cellular routers — site connectivity where no internet exists
More from Every1

Other Sites We Run

Run your site like a microgrid.

Request a DemoContact Us